CNG cylinder blasts have caused no accidents in Pakistan: APCNGA

4
196

The All Pakistan CNG Association (APCNGA) on Tuesday said no incidence of CNG cylinder blast ever took place in the country.

They said that because CNG supplies were limited, drivers were compelled to resort to using alternate fuels in an unsafe manner, which led to accidents. Ensuring uninterrupted CNG supply to consumers would put such incidents to an end.

Further, there is no law in Pakistan banning the fixing of CNG cylinders below seats, said APCNGA Supreme Council Chairman Ghiyas Abdullah Paracha.

He said that laws ensuring quality fitting of CNG kits were there and APCNGA has been acting on its plan to ensure international level safety standards but the pace is not satisfactory due to governmental mismanagement.

Ghiyas Paracha said that the transport sector is being closed on the pretext of the Gujrat incident despite the fact that reports of provincial departments, police, district administrations, Pakistan Hydrocarbon Development Institute and Ogra clearly indicate that no approved cylinder has ever blown up.

Different departments are blaming others for their incompetence while those who invested heavily in CNG and transport sector are suffering.

The CNG sector’s spokesman said that they have invested millions of rupees over the last ten years for developing a state-of-the-art checking system but the government has not been supportive of its execution.

Similarly, he said that they have provided Rs 20 million to the government to create awareness among the masses about CNG safety but to no avail.

APCNGA can check and ensure international safety standards in all commercial vehicles within six months only if the government departments cooperated, he claimed.

4 COMMENTS

  1. the actual cause that lead to cylinder's blast is using series PRD cylinder valve as well as using unapproved or defected Gas Cylinders because both of them working simultaneously together to overcome the high temperature that produced during the fire , the cylinder should stay safe for at least 12 minute before blast meanwhile, the thermal fusible device integrate in the cylinder valve has to activate during 2 : 5 minutes to vent the gas from inside the cylinder otherwise cylinder will blast specially in case of localized fire so , all CNG Vehicles should replace all cylinders valve with the new approved valve parallel independent PRD which is approved in the European standard .

    don,t hesitate to contact me for more information

    Eng. Khaled Hashem
    CNG conversion Gen. Manager .

    • SIr!
      I am carrying out the research on the CNG cylinders and integrating the safety system for that. I have designed an electronic system for that. But tell me if there is any case of the blast of the CNG cylinder due to failure of material? Also tell me the main causes of explosion of the CNG cylinders